We are a leading Manufacturer of test cabinets in delhi, test cabinets and test cabinet from New Delhi, India.
₹ 580000 Get Latest Price
Humidity Range | Ambient +5% to 95% RH |
Door Open | Alarm |
Test parameter | Damp Heat at 70 DegreeC with +- 3 DegreeC |
Temperature Range: | -20 DegreeC to 70 DegreeC or higher as per requirements |
Temperature Accuracy: | +- 0.2 DegreeC |
Country of Origin | Made in India |
Environmental Test Chambers are conceptualized and designed study and contemplate the effects of different environmental parameters such as humidity, temperature and light in various applications tests involving micro-organisms, plants, tissues, electronic components etc. apart from various customized industrial and research applications. Our Environmental Chambers have a variety of usage in R & D laboratories, research studies and product testing facilities across the globe. Standard Environment Chamber and Customized Environmental Test Chambers, specifically designed to meet the challenging demands of various scientists for individual and specialized research applications
Standard features
1.Double walled modular structure with 3" thick PUF insulation
2.Inside Stainless Steel and Outside Mild Steel Powder Coated or Stainless Stee
l 3.Heavy duty Caster wheel 2 front wheel Lockable & Back 2 wheel unlockable
4. Glass door with secure gasket for better observation of the samples (optional)
5.Heavy-duty door hinges and latches to maintain a secure and uniform seal.
6. stainless steal trays with adjustable height.
7. U shaped s.s. nichrome wire air heater.
8.humidity system with evaporation tray and reservoir tank with water level arrangement.
9. Uniform air forced circulation for uniformity air through out the chamber through blowers and circulation motors.
10. Thermostat sensor to cut off the supply in case of overshoot and undershoot of temperature giving audio visual alarm.
11. power supply works on 220V AC / 16 amp. Single phase 50Hz.
Temperature controller system
PLC or Digital dual LED with 0.1 °C steps readability and stability
Single setpoint, ramp & soak to 8 steps "Optional "
Audible visual alarm.
Set temperature according to the sample's testing working environment.
Auto tuning of controller Digital dual Display
Door Open Alarm
Temperature & Humidity High Deviation Alarm
Water input Failure Alarm
Temperature Range |
Temperature Range: -20°C to 70°C or higher as per requirements |
Temperature Accuracy: ± 0.2°C |
Temp Uniformity: ± 2.0°C |
Humidity Range |
Humidity Range Ambient +5% to 95% RH |
Humidity Accuracy: ± 2.0% RH |
Humidity Uniformity: ± 3.0% RH |
Test Parameters |
Damp Heat at 70°C with ± 3°C |
Cold test upto -20°C with ± 3°C |
Humidity 95% at 40°C with ± 3-4% RH and 3°C Temp |
₹ 140000 Get Latest Price
Door | Glass door with secure gasket for better observation of the samples |
Temperature Range: | -20 DegreeC Heating up to 70 DegreeC " Optional" |
Temperature Accuracy: | +- 0.2 DegreeC |
Humidity Range | Ambient + 5% to 95% RH |
Temperature controller system | Digital dual LED with 0.1 DegreeC steps readability and stability Single setpoint, ramp & soak to 8 steps |
Our Conditioning Test Chambers offers ideal humidity and temperature conditions required fow testing the effect of environmental changes on the product. The Reach-in Conditioning chamber can be widely used to evaluate the durability of various products. Getrus delivers customized products at the most economical rate and within the limited delivery period. Our Laboratory Conditioning Test Chambers use airtight modular construction for ease of installation and relocation. We can even custom design these chambers as per the specific environmental testing application.
Standard features
1.Double walled modular structure with 3" thick PUF insulation
2.Inside Stainless Steel and Outside Mild Steel Powder Coated or Stainless Steel
3.Heavy duty Caster wheel 2 front wheel Lockable & Back 2 wheel unlockable
4.Glass door with secure gasket for better observation of the samples (optional)
5.Heavy-duty door hinges and latches to maintain a secure and uniform seal.
6. stainless steal trays with adjustable height.
7. U shaped s.s. nichrome wire air heater.
8.humidity system with evaporation tray and reservoir tank with water level arrangement.
9. Uniform air forced circulation for uniformity air through out the chamber through blowers and circulation motors.
10. Thermostat sensor to cut off the supply in case of overshoot and undershoot of temperature giving audio visual alarm.
11. power supply works on 220V AC / 16 amp. Single phase 50Hz.
Temperature controller system
Digital dual LED with 0.1 °C steps readability and stability Single setpoint, ramp & soak to 8 steps "Optional "
Audible visual alarm.
Set temperature according to the sample's testing working environment. Auto tuning of controller Digital dual Display
Door Open Alarm
Temperature & Humidity High Deviation Alarm Water input Failure Alarm
Temperature Range |
Temperature Range: -20°C Heating up to 70°C " Optional" |
Temperature Accuracy: ± 0.2°C |
Temp Uniformity: ± 2.0°C |
|
Humidity Range |
Humidity Range Ambient + 5% to 95% RH |
Humidity Accuracy: ± 2.0% RH |
Humidity Uniformity: ± 3.0% RH |
Tarun Sharma (CEO)
Getrus International
A-23,RISHI NAGAR,RANI BAGH,New Delhi